4-3 Wiring Conforming to EMC Directives
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
4
System Design
Noise Filter for Power Supply Input
We recommend using a noise filter for the Servo Drive.
 If no-fuse breakers are installed at the top and the power supply line is wired from the lower duct,
use metal tubes for wiring or make sure that there is adequate distance between the input lines
and the internal wiring. If input and output lines are wired together, noise resistance will decrease.
 The noise filter must be installed as close as possible to the entrance of the control panel. Wire
as shown at the left in the following illustration.
Servo Drive Noise filter for power supply input
Phase Model Model
Rated
current
Leakage current
(60 Hz) max.
Manufac-
turer
Single-
phase
R88D-KNA5L-ECT-R SUP-EK5-ER-6
5 A
1.0 mA
(at 250 VAC)
Okaya
Electric
Industries
Co., Ltd.
R88D-KN01L-ECT-R
R88D-KN02L-ECT-R
Single-
phase
R88D-KN04L-ECT-R 3SUP-HU10-ER-6
10 A
3.5 mA
(at 500 VAC)
Single-
phase
R88D-KN01H-ECT-R SUP-EK5-ER-6
5 A
1.0 mA
(at 250 VAC)
3-phase
3SUP-HU10-ER-6
10 A
3.5 mA
(at 500 VAC)
Single-
phase
R88D-KN02H-ECT-R SUP-EK5-ER-6
5 A
1.0 mA
(at 250 VAC)
3-phase
3SUP-HU10-ER-6
10 A
3.5 mA
(at 500 VAC)
Single-
phase
R88D-KN04H-ECT-R SUP-EK5-ER-6
5 A
1.0 mA
(at 250 VAC)
3-phase 3SUP-HU10-ER-6
10 A
3.5 mA
(at 500 VAC)
Single/
3-phase
R88D-KN08H-ECT-R
R88D-KN10H-ECT-R 3SUP-HU30-ER-6
30 A
3.5 mA
(at 500 VAC)
R88D-KN15H-ECT-R
3-phase
R88D-KN20H-ECT-R 3SUP-HU50-ER-6
50 A
3.5 mA
(at 500 VAC)
R88D-KN30H-ECT-R 3SUP-HL50-ER-6B
50 A
8.0 mA
(at 500 VAC)
R88D-KN50H-ECT-R
R88D-KN06F-ECT-R FN258L-16-07
16 A
0.8 mA
(at 440 VAC/
50 Hz)
Schaffner
EMC Inc.
R88D-KN10F-ECT-R
R88D-KN15F-ECT-R
R88D-KN20F-ECT-R
R88D-KN30F-ECT-R FN258L-30-07
30 A
0.8 mA
(at 440 VAC/
50 Hz)