View or Change TCP/IP Settings
Menu System 4-19
Defaults to the last saved selection.
Procedure:
1. Do one of the following actions:
a. Press Menu to bypass.
b. Press Select to start the change mode.
2. For each digit:
a. Press Select to increment the flashing digit until the desired value appears.
b. Press Menu to set.
If you attempt to enter a value greater than 255 in either trio, all digits flash when
the last digit is set.
3. Press Menu to advance to the next submenu; or, press Select to restart the change
mode.
Note: If all digits flash, press either Select or Menu to clear; then,
press Select to restart the change more.
Gateway Hi Submenu
Note: Manufacturing ships drives with a static Gateway Hi set to
either
000.000
.or
255.255
Operator panel window shows
GWhaaa.bbb
.
Valid entries are 000-255 for each digit trio.
Defaults to the last saved selection.
Procedure:
1. Do one of the following actions:
a. Press Menu to bypass.
b. Press Select to start the change mode.
2. For each digit:
a. Press Select to increment the flashing digit until the desired value appears.
b. Press Menu to set.
If you attempt to enter a value greater than 255 in either trio, all digits flash when
the last digit is set.
3. Press Menu to advance to the next submenu; or, press Select to restart the change
mode.
Note: If all digits flash, press either Select or Menu to clear; then,
press Select to restart the change more.