EasyManuals Logo
Home>Polycom>Conference System>SoundStructure C16

Polycom SoundStructure C16 User Manual

Polycom SoundStructure C16
712 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #633 background imageLoading...
Page #633 background image
Command Protocol Reference Guide
A - 117
Description
This parameter sets the amount of delay applied to the audio signal, in sam-
ples. The sampling frequency is 48 kHz, which means that a sample is 20.83
microseconds. The maximum delay of 96000 samples is equivalent to 2
seconds.
delay_en
Enable Signal Delay
Description
This parameter enables (1) or disables (2) the delay algorithm.
fb_en
Enable Feedback Reduction
Description
This parameter enables (1) or disables (0) the feedback reduction algorithm.
Argument Argument value
Channel Type Virtual Channel
Value Type Boolean
Read/Write Mode Read/Write
Phys Chans
Conferencing Mic/Line Input, Conferencing Line Output,
Sound Reinforcement Mic/Line Input, Sound Reinforcement
Line Output, Analog Telephony Output Submix,
ConferenceLink Aux Input, ConferenceLink Aux Output
Virt Chans Mono, Stereo
Default 0
Event Source No
Argument Argument value
Channel Type Virtual Channel
Value Type Boolean
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans Mono, Stereo
Default 0
Event Source No

Table of Contents

Other manuals for Polycom SoundStructure C16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom SoundStructure C16 and is the answer not in the manual?

Polycom SoundStructure C16 Specifications

General IconGeneral
BrandPolycom
ModelSoundStructure C16
CategoryConference System
LanguageEnglish

Related product manuals