Service Call 501-582
D255/D256/M281/M282 6-34 SM
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC540-02 D Fusing Pressure Release Motor Error 2
The position detection sensor is not detected for 30 seconds
consecutively after the fusing pressure release motor is
activated.
ï‚§ Connector defective or disconnected
ï‚§ Drive transmission of the fusing pressure release motor
defective
ï‚§ Fusing pressure release motor defective
ï‚§ Connect-Left PCB defective
ï‚§ IOB defective
ï‚§ Connector defective or disconnected
Reconnect the following connectors. Then perform a
conduction inspection. If there is no conduction, replace the
connector.
 Fusing Pressure Release Motor – Connect-Left PCB
connector
 Connect-Left PCB – IOB connector
ï‚§ Drive transmission of the fusing pressure release motor
defective
Check the gears. If any gears are damaged, replace them.
ï‚§ Fusing pressure release motor defective
Replace the fusing pressure release motor.
ï‚§ Connect-Left PCB defective
Replace the Connect-Left PCB.
ï‚§ IOB defective
Replace the IOB.