Service Call 622-691
D255/D256/M281/M282 6-54 SM
6.7.2 SC600 (CONTROLLER)
SC No. Type
Details (Symptom, Possible Cause, Troubleshooting
Procedures)
SC641-00 D Communication error between BiCU and Controller board.
Controller board does not respond after BiCU tries to
communicate three times.
ï‚§ Controller board software error
ï‚§ Connect error between BiCU and Controller board
ï‚§ BiCU software error
ï‚§ Check connections between Controller board and BiCU.
ï‚§ Turn the main power OFF then ON.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC670-01 D Engine does not start up during the staring up
ï‚§ /ENGRDY signal was not asserted when the machine was
turned on.
ï‚§ PCI I/F is not linked up when the machine returns from
energy saver mode.
ï‚§ EC/PC/SC response was not received within specified time
from power on.
ï‚§ Writing to Rapi driver failed (the other party not found
through PCI).
ï‚§ Connection defect between controller board and BiCU.
ï‚§ BiCU is down / unstable
Engine board does not start up.
Refer to page 6-118 "SC670 (engine start up error) is displayed".