Security Features
SM Appendix 4-17 D255/D256/M281/M282
Configuration
ï‚§ Without admin privileges, even authenticated users will be unable to access the DS via
WIM.
Bit 7:
Bit 7 = 0 (default): Allows anyone (guests, users, admins) access to the DS via WIM.
Bit 7 = 1: Only administrators and authenticated users can access the DS via WIM.
The most restrictive result of combining these three configurations will take priority. So for
example:
Bit 0 = 0
Bit 1 = 1
Bit 7 = 1
As Bit 1 = 1 is the most restrictive of the three, it will take presedence over the other two and only
administrators will be able to access the DS via WIM.
ï‚§ In order for SP5-885-020 to have any effect, the Document Server must be enabled
(SP5-967-001=0). For information about SP5-967-001, refer to Disabling the Document
Server using System SP5-967-001 and Printer SP1-006-001.
ï‚§ Access to the entire "Job" menu can be restricted using SP 5-888-001. For details, refer
to Use of SP 5-888-001 to restrict access to the "Job" menu on WIM.