3.SP Mode Tables
48
2-
016-
006
Lubricant Apply Operation Page Setting 4: High Temp. ENG* [ 0 to 999 / 20 /
1page ]
2-
016-
007
Lubricant Apply Operation Coverage Threshold 1: Low
Speed
ENG* [ 0 to 100 / 10 /
0.01% ]
2-
016-
008
Lubricant Apply Operation Coverage Threshold 2: Low
Temp.
ENG* [ 0 to 60 / 20 / 0.01% ]
2-
016-
010
Lubricant Apply Operation Coverage Threshold 4: High
Temp.
ENG* [ 0 to 100 / 20 /
0.01% ]
2-
016-
011
Lubricant Apply Operation Application Time:1 ENG* [ 0 to 99 / 10 / 1sec ]
2-
016-
012
Lubricant Apply Operation Application Time:2 ENG* [ 0 to 99 / 10 / 1sec ]
2-
016-
013
Lubricant Apply Operation Application Time:3 ENG* [ 0 to 99 / 10 / 1sec ]
2-
016-
014
Lubricant Apply Operation Application Time:4 ENG* [ 0 to 99 / 5 / 1sec ]
2-
016-
033
Lubricant Apply Operation Page Setting 5: Low Temp. ENG* [ 0 to 999 / 20 /
1page ]
2-
016-
034
Lubricant Apply Operation Image Area Threshold 5:
Low Temp.
ENG* [ 60 to 100 / 60 /
0.01% ]
2-
016-
035
Lubricant Apply Operation Application Time:5 ENG* [ 0 to 99 / 3 / 1sec ]
2-
016-
036
Lubricant Apply Operation Temperature Threshold:
Low 2
ENG* [ 0 to 50 / 15 / 1deg ]
2-
101-
001
Registration Adjustment Color Main Dot: Bk ENG* [ -512 to 511 / 0 /
1dot ]