104 Publication IASIMP-QS003B-EN-P - October 2009
Chapter 9 Create a Project in RSLogix 5000 Programming Software
Configure 1768-ENBT Ethernet Module
Required for EtherNet/IP System
1. Under I/O
Configuration, right-click
1768 Bus and select New
Module.
2. Expand
Communications, select
1768-ENBT/A, and click
OK.
3. In the New Module
dialog box:
a. Enter a Name for the
module.
b. Enter the IP Address
from Chapter A
.
c. Set the Slot to 1.
d. Select Disable Keying.
e. Uncheck Open Module
Properties.
f. Click OK.
For EtherNet/IP systems,
skip to page 107
, Configure
1769 Local I/O Modules.