LOGO! Manual
A5E00067781 01
74
Parameter inputs
There some inputs at which you do not apply signals.
Instead, you parameterize the function block with certain
values.
Par (parameter):
This input is not wired. Here you set parameters for the
block.
T (time):
This input is not wired. Here you set times for a block.
No (number):
This input is not wired. Here you set time bases.
P (priority):
This input is not wired. Here you set priorities.
4.3.2 Time Response
Parameter T
With some of the special functions it is possible to parame-
terize a time value T. When specifying the time, note that
the values to be entered depend on the time base set:
Time Base _ _ : _ _
s (seconds) Seconds :
1
/
100
seconds
m (minutes) Minutes : Seconds
h (hours) Hours : Minutes
B01:T
T=04.10h+
Setting the time T for 250 minutes:
Unit hours (h):
04.00 hours 240 minutes
00.10 hours +10 minutes
= 250 minutes
LOGO! Functions