Maintaining and repairing the device
6.6 Configure IOT2050 SM
SIMATIC IOT2050
Operating Instructions, 03/2024, A5E39456816-AF
87
Nov 10 00:26:32 iot2050-debian IOT2050-EventRecord[500]:
IOT2050_EVENTS.eio: 2024-1-10 7:3:57 [4] slot1 loss
Nov 10 00:26:32 iot2050-debian IOT2050-EventRecord[500]:
IOT2050_EVENTS.eio: 2024-1-10 7:2:57 [5] slot2 loss
6.6.2.6 Controller status
Controller status shows in : /eiofs/controller/status
State: startup|config|running|idle
State
Description
startup
eiofs is waiting for time synchronization with IOT2050 SM.
config
eiofs is scanning and configuring connected S7-1200 signal modules.
running
eiofs has configured all connected modules.
idle
Not configured, not connected, or other critical errors occurred.