4.5 Assembly in a humid atmosphere
Information
If a fan / motor is stationary for long periods in a humid atmosphere, it should be switched ON for
minimum of two hours every month to remove any moisture that may have condensed within the
motor.
4.6 Motorheating
A continuous power supply is required for safe operation down to the minimum permitted outer
temperature (
technical data).
If the motor is not switched on with an existing power supply (no setting signal, switch off by enable),
the motorheating switches back off automatically at a controller inside temperature of -19 °C and
heating up to -15 °C.
Heating takes place via the motor winding whereby a current is induced which cannot cause rotation.
Assembly instructions ECblue Mounting
L-BAL-F065-GB 1617 Index 004 Part.-No. 00702801-GB
14/28
178