20.PROFINET COMMUNICATION
20.9.3.12 Point Table Mode Objects
(1) Target point table (P11616)
In the point table mode (pt), specify the point table No. to execute. In the indexer mode (idx), set the next
station No to execute. The settable values vary depending on the control mode.
FFFFh to 00FFh (-1 to 255)
0000h to 00FEh (0 to 254)
(2) Point demand value (P11624)
In the point table mode (pt), the currently specified point table No. is returned. In the indexer mode (idx),
the currently specified next station No. is returned. The returned values vary depending on the control
mode.
FFFFh to 00FFh (-1 to 255)
0000h to 00FEh (0 to 254)
(3) Point actual value (P11625)
In the point table mode (pt), the completed point table No. is returned. In the indexer mode (idx), the
completed station No. is returned. The returned values vary depending on the control mode.
FFFFh to 00FFh (-1 to 255)
0000h to 00FEh (0 to 254)