5. PARAMETERS
5 - 13
5.1.7 Positioning control parameters ([Pr. PT_ _ ])
No.
Symbol
Name
Initial
value
Unit
Operation
mode
Standard
PT01
**CTY
Command mode selection
0300h
PT02
For manufacturer setting
0001h
PT03
*FTY
Feeding function selection
0000h
PT04
For manufacturer setting
0000h
PT05
ZRF
Home position return speed
100.00
[r/min]
PT06
CRF
Creep speed
10.00
[r/min]
PT07
ZST
Home position shift distance
0
[µm]/
10
-4
[inch]/
10
-3
[degree]/
[pulse]
PT08
For manufacturer setting
0
PT09
DCT
Travel distance after proximity dog
0
10
STM
[µm]/
10
(STM-4)
[inch]/
10
-3
[degree]/
[pulse]
PT10
ZTM
Stopper type home position return stopper time
100
[ms]
PT11
ZTT
Stopper type home position return torque limit value
15.0
[%]
PT12
CRP
Rough match output range
0
10
STM
[µm]/
10
(STM-4)
[inch]/
10
-3
[degree]/
[pulse]
PT13
For manufacturer setting
100
PT14
0
PT15
LMPL
Software limit +
0000h
10
STM
[µm]/
10
(STM-4)
[inch]/
10
-3
[degree]/
[pulse]
PT16
LMPH
0000h
PT17
LMNL
Software limit -
0000h
10
STM
[µm]/
10
(STM-4)
[inch]/
10
-3
[degree]/
[pulse]
PT18
LMNH
0000h
PT19
*LPPL
Position range output address +
0000h
10
STM
[µm]/
10
(STM-4)
[inch]/
10
-3
[degree]/
[pulse]
PT20
*LPPH
0000h

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals