19 - 38
19EtherNet/IP COMMUNICATION
19.5.4.4 Profile velocity mode (pv)
The following shows the functions and related objects of the profile velocity mode (pv).
Velocity
trajectry
generator
×
×
×
×
Position actual internal value (6063h)
×
×
×
Velocity
limit
function
Acceleration
limit
function
Velocity
control
Torque
control
Torque limit value (60E0h, 60E1h)
Motion profile type (6086h)
Profile acceleration (6083h)
Profile deceleration (6084h)
Quick stop deceleration (6085h)
Quick stop option code (605Ah)
Target velocity (60FFh)
Max profile velocity (607Fh)
Max motor speed (6080h)
Gear ratio (6091h)
Polarity (607Eh)
Velocity demand value (606Bh)
Position actual value (6064h)
Velocity actual value (606Ch)
Torque actual value (6077h)
Motor
Encoder
(1) Related object
Class ID
Ins ID
Attr
ID
Acces
s
Name
Data
Typ
e
Default
Description
64h
60FFh
0
Get/S
et
Target velocity
DIN
T
Command speed
Unit: Vel unit (0.01 r/min or 0.01
mm/s)
607Fh
0
Get/S
et
Max profile velocity
UDI
NT
2000000
maximum speed
Unit: Vel unit (0.01 r/min or 0.01
mm/s)
6080h
0
Get/S
et
Max motor speed
UDI
NT
Servo motor maximum speed
Unit: r/min
6083h
0
Get/S
et
Profile
Acceleration
UDI
NT
0
Acceleration at start of movement to
target position
Unit: ms
6084h
0
Get/S
et
Profile
deceleration
UDI
NT
0
Deceleration at arrival at target
position
Unit: ms
6085h
0
Get/S
et
Quick stop
deceleration
UDI
NT
100
Deceleration at deceleration to a
stop by Quick stop
Unit: ms
6086h
0
Get/S
et
Motion profile type
INT
0
Acceleration/deceleration type
selection
-1: S-pattern
0: Linear ramp (not supported)
(Note)
1: Sin
2
ramp (not supported) (Note)
2: Jerk-free ramp (not supported)
(Note)
3: Jerk-limited ramp (not supported)
(Note)
605Ah
0
Get/S
et
Quick stop option
code
INT
2
Operation setting for Quick stop
Refer to section 5.6.
6063h
0
Get
Position actual
internal value
DIN
T
Current position (Enc inc)
6064h
0
Get
Position actual
value
DIN
T
Current position (Pos units)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals