7.1.4. Connection
The product is delivered with the following conguration:
Connectors 101 to 106, I 1/2 to I 7/8, located on the right side of the controller are associated with switch I
Connectors 201 to 206, II 1/2 to II 7/8, located on the left side of the controller are associated with switch II.
1
2
Load
Source
Source
II
I
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
To D10
To D20
64B 63B
64B 63B
417 416 415 414 413
207 208 209 210
417 416 415 414 413
207 208 209 210
7172 74
7172 74
ATyS t
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
ATyS p
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
ATyS g
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
To D10
To D20
64B 63B
64B 63B
417 416 415 414 413
207 208 209 210
417 416 415 414 413
207 208 209 210
7172 74
7172 74
ATyS t
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
ATyS p
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
ATyS g
Aux Supply-2
Power
208-277 Vac ±20%
(166-332Vac 50/60 Hz)
L/N - 201
N/L - 202
Aux Supply-1
Power
208-277 Vac ±20%
(166-332Vac 50/60 Hz)
101 - L/N
102 - N/L
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
To D10
To D20
64B 63B
64B 63B
417 416 415 414 413
207 208 209 210
417 416 415 414 413
207 208 209 210
7172 74
7172 74
ATyS t
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
ATyS p
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
ATyS g
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
To D10
To D20
64B 63B
64B 63B
417 416 415 414 413
207 208 209 210
417 416 415 414 413
207 208 209 210
7172 74
7172 74
ATyS t
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
ATyS p
Dual auxiliary supply:
Uc 208-277V~ +/-20% 50/60Hz
Power comsumption: 22VA
See instruction sheet
ATS CONTROLLER
ATyS g
Voltage Sensing
Source II - 1Ph / 3Ph
0 - 332 / 575
1/2 - 203
3/4 - 204
5/6 - 205
7/8 - 206
Voltage Sensing
Source I - 1Ph / 3Ph
0 - 332 / 575
7/8 - 103
5/6 - 104
3/4 - 105
1/2 - 106
CAUTION
It is recommended to connect power and sensing with the ATyS voltage sensing and power
supply kit available as an accessory.
In this case ensure to mount the kit before connecting the power cables.

Table of Contents

Other manuals for socomec ATyS t

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the socomec ATyS t and is the answer not in the manual?

socomec ATyS t Specifications

General IconGeneral
Brandsocomec
ModelATyS t
CategorySwitch
LanguageEnglish

Related product manuals