237
Operation Settings
Chapter 17 Control Panel Setup
Settings for the Flexi Pad and Wipe
Snapshot Menus
Makes settings for the display of buttons in the Flexi Pad
and menus.
1
Open the Engineering Setup >Panel >Operation
>Flexi Pad Mode menu (7326.3).
2
Make the following settings, as required.
Settings for memory recall buttons in the Wipe
Snapshot menu and DME Wipe Snapshot
menu: Press [Pattern] or [Register Name] in the
<Wipe/DME Display> group to select the buttons.
Settings for memory recall buttons in the Misc
>Snapshot menu: Press [Register No] or
[Register Name] in the <Snapshot/Effect Display>
group to select the buttons.
Coupling the transition type selection with the Flexi
Pad mode selection: To make the Flexi Pad mode
selection change automatically when [WIPE] or
[DME] is selected in the transition control block,
press [Wipe/DME Auto Deleg], turning it on.
Button indications in the memory recall section:
When the Flexi Pad mode is [WIPE] or [DME],
for the button indications in the memory recall
section, select [Pattern] or [Register Name] in the
<Wipe/DME Display> group. When the mode is
[Snapshot], [Effect], or [MCRO], select [Register
No] or [Register Name] in the <Snapshot/Effect
Display> group.
Setting the Button Operation Mode
1
Open the Engineering Setup >Panel >Operation
>Custom Button menu (7326.4).
2
Make the following settings as required.
Operation mode during an auto transition: For the
operation mode when the [AUTO TRANS] or
[TAKE] button is pressed once more during an
auto transition, select [Continue] or [Cancel] in the
<Auto Trans/Take> group.
Continue: Continues the transition.
Cancel: Cancels the transition and returns to the
state before starting the transition.
Operation mode during keyframe execution: For
the operation mode when the [RUN] button is
pressed once more during effect execution, select
[Continue] or [Cancel] in the <Run> group.
Continue: Continues the effect.
Cancel: Cancels the effect and returns to the
state before starting the execution.
Interchanging the [AUTO TRANS] and [CUT]
buttons: To interchange the [AUTO TRANS] and
[CUT] buttons in the transition control block,
press the [Auto Trans/Cut Swap] button, turning it
on.
Transition preview operation mode: For the
operation mode of the [TRANS PVW] button,
select [Lock] or [Hold] in the <Trans Pvw> group.
The setting as to whether to use the “One-time
mode” in which the transition preview terminates
when the transition completes, or to use button
control, is made on the switcher side (1 p. 250).
[KEY] button operation mode for 2nd row buttons
in the cross-point control block: When a bus is
selected with the 1st row buttons, specify the
[KEY] button operation mode in the <Key Source
Bus Select Mode> group, as follows.
Key: If you select this, the [KEY] button is
always lit, and this mode allows only key signals
to be selected with the cross-point buttons.
Video & Key: The [KEY] button is enabled,
and either video or key signals can be selected.
Operation mode of the [XPT HOLD] buttons in the
1st row of the cross-point control block: Sets the
operation mode of the [XPT HOLD] buttons
assigned in the 1st row in the <Xpt Hold> group,
as follows.
A/B Bus: When the [XPT HOLD] button is
pressed, turning it on, enables only A bus and B
bus cross-point hold.
All Bus: When the [XPT HOLD] button is
pressed, turning it on, enables cross-point hold
for all buses used in the corresponding bank.
(A/B bus, Key1 to Key4 bus, utility bus)
Setting the Operation Mode of the
[ALL] Button in the Transition
Control Block
Specify the next transition selected by pressing the [ALL]
button in the transition control block.
If everything here is set to Off, then pressing the [ALL]
button does not change the specification of the next
transition.
1
Open the Engineering Setup >Panel >Operation
>Custom Button >Next Trans All menu (7326.11).
2
Press the button for the next transition you want to
select with the [ALL] button, turning it On.
Notes

Table of Contents

Other manuals for Sony MVS-3000 System

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony MVS-3000 System and is the answer not in the manual?

Sony MVS-3000 System Specifications

General IconGeneral
BrandSony
ModelMVS-3000 System
CategorySwitch
LanguageEnglish

Related product manuals