Wipe Settings for Independent Key Transitions
Chapter 5 Wipes
1
Open the M/E-1 >Wipe >Main Modify menu (1155).
2
Press [Aspect], turning it on.
3
Set the following parameter.
Replicating the wipe pattern
(Multiplication)
The same pattern can be repeated horizontally and
vertically or both, up to 63 times.
The [Invert Type] parameter allows you to select one of the
following four replication layouts.
1: All replications in the same orientation
2: Even-numbered rows staggered
3: Even-numbered columns and rows inverted
4: Even-numbered columns and rows inverted, and even-
numbered rows staggered
1
Open the M/E-1 >Wipe >Main Modify menu (1155).
2
Press [Multi], turning it on.
3
Set the following parameters.
Possible combinations of wipe patterns
and modifiers
Wipe Modify Clear
Press [Default Recall] at the lower left of the menu screen,
turning it on, then press the [Wipe] VF5 button to return
the wipe settings to their initial status.
For details about initial status, 1 “Saving User-Defined
Settings” (p. 214).
Wipe Settings for
Independent Key
Transitions
You carry out independent key transition wipe setting
operations using the Wipe Adjust menu for each keyer.
This section describes an example using key 1 on the M/E-
1 bank.
Open the M/E-1 >Key1 >Transition menu (1116), select
[Wipe Adjust], and display the Key1 Wipe Adjust menu
(1116.1).
For an overview of independent key transitions,
1 “Independent Key Transitions” (p. 57).
No. Parameter Adjustment
1 Aspect Aspect ratio
Negative values expand
vertically.
Positive values expand
horizontally.
Aspect Off Aspect On
Multi Off Multi On
No. Parameter Adjustment
1 H Multi Number of repetitions of pattern
horizontally
2 V Multi Number of repetitions of pattern
vertically
3 Invert Type Replication layout
Modifier Wipe pattern (pattern number)
Available Not available
Direction 1 to 24
Edge 1 to 24
Positioner 17, 18, 21 to 24 1 to 16, 19, 20
Rotation 1 to 24
Aspect ratio 9 to 16, 19 to 24 1 to 8, 17, 18
Multiplication 1 to 24

Table of Contents

Other manuals for Sony MVS-3000 System

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony MVS-3000 System and is the answer not in the manual?

Sony MVS-3000 System Specifications

General IconGeneral
BrandSony
ModelMVS-3000 System
CategorySwitch
LanguageEnglish

Related product manuals