7.5 REQUESTING SPARE PARTS
After verifying the problem with a specialized technician, When requesting spare parts, after please say clearly :
Model of the item.
Serial number of the item.
Motivation of the request of support.
Quantity of the spare part.
Possibly, enclose also a picture of the part to be ordered.
8 MESSAGES OF ERROR AND SOLUTIONS
MESSAGE
BREAKDOWN
MALFUNCTION
ERROR SOLUTIONS
Er
Ensure that all the cables
are included in the terminal
generic error or/
Internal error of the probe
If the cable is tore off, insert it
again and screw it up
Er1
Ensure that all the cables
are included in the terminal
error of the room probe
If the cable is tore off, insert it
again and screw it up
Er2
Ensure that all the cables
are included in the terminal
error of the room probe
If the cable is tore off, insert it
again and screw it up
Er3
Ensure that all the cables
are included in the terminal
error of the condenser probe
If the cable is tore off, insert it
again and screw it up
Blasting time too long
Check if the evaporator is
blocked with ice
Leave the door open for at
least 15 min to melt the ice
Check if the product is loaded
correctly and does not exceed
Lighten the load of trays
and grills
Check if the internal fan is
spinning
Contact the assistance
Ensure that the laboratory
temperature is not too high
and with high percentage of
humidity
Contact the assistance
Failed conservation of the food
at the end of the blasting cycle
Contact the assistance
DR
The door is open The door is open
Check that the door is
properly closed
General product information:
code BSFjkz (identification of single particular code of the family BSF -
Blast Chiller - Shock Freezer)
"BSF" TYPE OF PRODUCT
possible options:
BSF = Blast Chiller - Shock Freezer
"j" grids or pans capacity of EUT
possible options:
03TS = capacity: 3 grids or pans
05TS = capacity: 5 grids or pans
07TS = capacity: 7 grids or pansv
10TS = capacity: 10 grids or pans
10TP = capacity: 10 grids or pans
15TS = capacity: 15 grids or pans
20TS = capacity: 20 grids or pans
"k" additional configuration of EUT
possible options:
SW Without unit - electric defrosting system
CW With unit - electric defrosting system
SX Without unit - Hot gas defrosting system
CX With unit - Hot gas defrosting system
SY Without unit - manual defrosting system
CY With unit - manual defrosting system
“z” additional configuration of EUT
possible options:
Y = With manual defrosting system (il compressore si
spegne)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tecnodom Attila Series and is the answer not in the manual?

Tecnodom Attila Series Specifications

General IconGeneral
BrandTecnodom
ModelAttila Series
CategoryChiller
LanguageEnglish

Related product manuals