E6581697
F-50
6
6.15.7 Reverse-run prohibition
f311 : Reverse-run prohibition
ď‚· Function
This function prevents the motor from running in the forward or reverse direction when it receives the
wrong operation signal.
[Parameter setting]
Title Function Adjustment range Default setting
f311
Reverse-run prohibition
0: Forward/reverse run permitted
1: Reverse run prohibited
2: Forward run prohibited
0
6.16 Droop control
f320 : Droop gain
f323 : Droop insensitive torque band
f324 : Droop output filter
ď‚· Function
Droop control has the function of preventing loads from concentrating at a specific motor because of
a load imbalance when multiple inverters are used to operate one machine.
These parameters are used to allow the motor to “slip” according to the load torque current. Using
these parameters, the insensitive torque band and the gain can be adjusted.
[Parameter setting]
Title Function Adjustment range Default setting
f320 Droop gain 0.0-100.0 (%) 0.0
f323 Droop insensitive torque band 0-100 (%) 10
f324 Droop output filter 0.1-200.0 100.0

Table of Contents

Other manuals for Toshiba TOSVERT VF-MB1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-MB1 and is the answer not in the manual?

Toshiba TOSVERT VF-MB1 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-MB1
CategoryInverter
LanguageEnglish

Related product manuals