Engine Shutdown
Allow the engine to run at low idle, in neutral, for a few minutes after operations are completed. In this way after-
boiling is avoided at the same time as temperature equalization takes place. This is especially important when
the engine has been run at high rpm or under heavy load.
Stop the Engine
Stopping Using the Start/Stop Panel
1 Disengage the drive/reverse gear by putting the
control lever in Neutral (N).
2 Stop the engine(s) by pushing the STOP button(s).
Stopping Using the e-Key Panel
IGNITION IGNITION
START/STOP
START/STOP
P0016518
1 Disengage the drive/reverse gear by putting the
control lever in Neutral (N).
2 Push the STOP button(s). Release the button(s)
when the engine(s) has/have stopped.
Turn the Ignition Off and Lock the EVC system
To turn the ignition off, press the IGNITION button.
The green lamp in the IGNITION button is switched
off to indicate that the ignition is off.
To lock the EVC system, hold the key fob in front of
the symbol on the e-Key panel.
A flashing red light indicates that the system is locked.
Stop using key
If a station is active and locked the engine(s) can only
be started and stopped from that station.
1 Disengage the reverse gear by putting the control
lever in neutral.
2 Turn the key to stop position “S”. The starter key
must be in the i “0” position or removed before main
switches are switched off..
IMPORTANT:
Make sure the ignition is turned off before the main
switches are switched off. Otherwise the alternator and
electronics could be damaged.
47708638 09-2016 © AB VOLVO PENTA 69