8 Use and operation DPU 130Le
71
Operator's manual
Calling up error memory
All errors (max. 56) are saved in the error memory with the appropriate error
code. The hour of operation in which the error occurred is also saved.
The system issues a serial number to each error. The most recent error is saved
with the highest number.
The display screen displays the following information in sequence:
Serial number, hour of operation, error code.
Error message.
1. Call up the error me
mory entry in the diagnostic menu.
2. Push the left control lever on the remote control forward or backward to select
the saved error.
Note: The error message is displayed as a numerical code if you set the
menu language to numerical code display.
You can match each error code to the corresponding error message in
the chapter Troubleshooting.
8.9 Using the configuration menu
Note: The machine configuration manual explains how to use the
configuration menu.
Item Designation Item Designation
1 Serial number 3 Error code
2 Hour of operation

Table of Contents