Appendix 5. Q&A
Q1: What is BB and run on the panel?
1. BB standby state, without enabling, the motor is in the state of power failure.
2. Run running state, with enabling, the motor is in the power on state.
Q2: How to check and set the parameters?
Refer to chapter 4.6
Q3: How to change the parameters in enabled status?
P5-20=0000, enabling is invalid, P5-20=0010, enabling when power on, no need to power on again.
The default value is 0001, which means input signal from SI1, SI1 connects to low voltage, +24V
connects to high voltage (refer to chapter 3.2.2)
Q4: How to restore out of factory settings?
P5-20=0000 enabling is invalid, F0-01=1.
Q5: Which model supports bus mode?
DS5E series supports XNET communication (max 20-axis)
DS5C series supports EtherCAT communication (max 32-axis)
Q6: How to wiring for brake motor? How to modify parameters for slight slip of brake motor after
power failure?