7 Alarm
7.1 Alarm code list
Historical record: "" means that historical alarms can be recorded; "" is not recorded;
The column that can be cleared: "" represents the alarm that can be cleared; "" represents the alarm
that cannot be cleared.
Alarm code
Code
Explanation
Property
Servo
status
when
alarming
Historical
records
Can be
cleared
Whether
power on
is needed
to clear
the alarm
EEEE
1
EEEE1
Communication error
between panel and CPU
No
Servo run
2
EEEE2
No
Servo run
3
EEEE3
No
Servo run
4
EEEE4
No
Servo run
01
0
E-010
Firmware version mismatch
Yes
Servo run
3
E-013
FPGA Loading Error
Yes
Servo run
5
E-015
Program running error
Yes
Servo run
6
E-016
Processor Running Error
No
Servo run
7
E-017
Processor Running Timeout
Yes
Servo run
9
E-019
System password error
Yes
Servo run
02
0
E-020
Parameter loading error
Yes
Servo run
1
E-021
Parameter range beyond
limit
No
Servo run
2
E-022
Parameter conflict
No
Servo run
3
E-023
Sampling channel setting
error
Yes
Servo run
4
E-024
parameter lost
No
Servo run
5
E-025
Erase FLASH error
No
Servo run
6
E-026
Initialization FLASH error
No
Servo run
8
E-028
EEPROM write in error
No
Servo run
03
0
E-030
Bus voltage overvoltage
No
Servo off
04
0
E-040
Bus voltage under voltage
Low grid voltage
No
Servo run
Bus voltage under voltage
Bus voltage undervoltage
caused by power failure of
driver
No
Servo off
1
E-041
Driver power down
No
Servo run
3
E-043
Bus Voltage Charging
Failure
No
Servo off
4
E-044
Three phase voltage input
phase loss
No
Servo off
06
0
E-060
Module temperature too high
No
Servo run
1
E-061
Motor overheating
Yes
Servo run
3
E-063
Thermocouple disconnection
alarm
No
Servo run
08
0
E-080
Overspeed alarm
No
Servo off
09
2
E-092
Analog Tref
Zero-Calibration Over limit
No
Servo run
3
E-093
Analog Vref
Zero-Calibration Over limit
No
Servo run
10
0
E-100
Excessive position deviation
No
Servo run