4.
FAN
BELT
TENSION
Loosen the charging generator mounting bolt and.
the belt adjusting bolt, and adjust
the fan belt
tension so that there is 0.4
-
0.6 in. (10 to
15
mm) of play at a point midway between the fan
pulley and the generator pulley, and then tighten
each of the bolts.
5.
AIR
VENTING
(Bleeding)
1
Put fuel into the fuel tank.
(3)
Carry out the same procedure given in
(2)
with the air venting plug
(B).
14)
Loosen the
air
venting plug of the fuel pump
in the same manner as described in
(2)
to re-
lease any air.
(5)
Loosen the injection valve side of the fuel
injection pipes.
(2)
Loosen the air venting plug
(A)
of the fuel
filter, allow fuel to flow from
!he plug until the
fuel flowing out
is
free of air bubbles, and then
tighten the air venting plug.