(6)
Put the shift levers in neutral, the throttle
lever in running position, move the decompression
lever, and then turn the engine with the
.starter
motor.
(7)
As soon as fuel starts reaching the No.
1
and
No. 2 cylinders from the injection valve side,
ti-
ghten the fuel injection pipes for each cylinder.
(8)
Move the decompression lever once again
and turn the starter motor. If
a
spurting sound
which indicates injection
is
taking place
is
heard,
the venting
is
compteted.
6.
OTHER MEASUREMENTS AND INSPEC-
TIONS.
(1)
Lube oil pressure: 21.34-35.56 psi
(1.5-
2.5
kglcm'
)
Attach
a
pressure gauge to the fitting of the lube
oil pressure switch and measure lube oil pressure.
'7
I
,
(2)
Top clearance: 0.030-0.022 in. (0.67+0.1
mm)
a)
Extract the
combution chamber (rear and
front), insert fuse rod through nozzle mount-
ing port, and turn flywheel.
b)
Squash the fusebetween the cylinder head
and the piston crown.
C)
Measure the thickness of the squashed
fuse using a micrometer.