Temperature, High Precision Voltage Isolation Module (701265)
Item Specifications
Standard operating conditions Temperature: 23 ± 5°C
Humidity: 20 to 80% RH
After a 30 minute warm-up and after calibration
Function Temperature (thermocouple) or voltage measurement (switchable)
Effective measurement range [Voltage measurement] 20 div (display range: 10 div)
Number of input channels 2
Input coupling TC, DC, GND
TC: Temperature (thermocouple) measurement
DC: Voltage measurement (DC coupling)
Data update rate 500 Hz
Input type Isolated unbalanced
Measurement range/accuracy
1
For the thermocouple
standards, see the 701261
specifications.
[Voltage measurement] Voltage sensitivity: 100 µV/div to 10 V/div (1-2-5 steps)
Voltage accuracy: ±(0.08% of 10 div + 2 µV)
[Temperature measurement]
2
Type Measurement Range Accuracy
K
E
J
T
L
U
N
−200 to 1300°C
−200 to 800°C
−200 to 1100°C
−200 to 400°C
−200 to 900°C
−200 to 400°C
0 to 1300°C
±(0.1% of reading + 1.5°C)
Except ±(0.2% of reading + 1.5°C) for
−200°C to 0°C
R
S
0 to 1700°C
0 to 1700°C
±(0.1% of reading + 3°C)
Except, 0 to 200°C: ±8°C
200 to 800°C: ±5°C
B 0 to 1800°C ±(0.1% of reading + 2°C)
Except, 400 to 700°C: ±8°C
Effective range is 400 to 1800°C
W 0 to 2300°C ±(0.1% of reading + 3°C)
Au7Fe
3
0 to 300K 0 to 50K: ±4K
50 to 300K: ±2.5K
Frequency characteristics
1
(−3 dB point a when sine wave
of amplitude ±3 div is applied)
[Voltage measurement] DC to 100 Hz
[Temperature measurement] DC to 100 Hz
Maximum input voltage
4
(at a frequency of 1 kHz or less)
Both temperature and voltage input: 42 V (DC + ACpeak)
Maximum rated voltage to
ground
5
Between input and case
Between inputs
(at a frequency of 1 kHz or
less)
Both temperature and voltage input: 42 V (DC + ACpeak) (CAT II, 30 Vrms)
Vertical resolution [Voltage measurement] During voltage input: 2400 LSB/div
[Temperature measurement] When measuring temperature: 0.1°C
Low frequency −3 dB point when
AC coupled
[Voltage measurement] 0.5 Hz or less
Input connector Binding post
Input impedance Approx. 1 MΩ
Common mode rejection ratio [Voltage measurement] 80 dB (50/60 Hz) or more (typical value
6
)
[Temperature measurement] 120 dB or more (50/60 Hz, with 2-Hz filter ON, signal source
resistance of 500 Ω or less) (typical value
6
)
Residual noise level
(input section shorted)
[Voltage measurement] ±4 µV or ±0.01 div, whichever is greater (typical value
6
)
A/D converter resolution [Voltage measurement] 16 bits (2400 LSB/div)
Temperature coefficient [Voltage measurement] Zero point: ±(0.01% of 10div)/°C + 0.05 µV/°C) (typical value
6
)
Gain: ±(0.02% of 10 div)/°C (typical value
6
)
Reference junction
compensation accuracy
(when the input terminal
temperature is balanced)
K, E, J, T, L, U, N: ±1°C
R, S, B, W: ±1.5°C
Au7Fe: ±1K
6.13 Module Specifications

Table of Contents

Other manuals for YOKOGAWA DL350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL350 and is the answer not in the manual?

YOKOGAWA DL350 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL350
CategoryRecording Equipment
LanguageEnglish

Related product manuals