Maintenance and Troubleshooting
191
4-Slot Charge Only Cradle with Battery Charger Troubleshooting
During
communication, no
data transmits, or
transmitted data was
incomplete.
Device removed from
cradle during
communications.
Replace device in cradle and retransmit.
Incorrect cable
configuration.
Ensure that the correct cable configuration.
Device has no active
connection.
An icon is visible in the status bar if a connection is
currently active.
Table 17 Troubleshooting the 1-Slot Charge Only Cradle (Continued)
Symptom Possible Cause Action
Table 18 Troubleshooting the 4-Slot Charge Only Cradle with Battery Charger
Problem Cause Solution
Battery is not
charging.
Device
removed from
the cradle too
soon.
Replace the device in the cradle. The standard battery
charges from fully depleted to 90% in approximately three
hours. The extended battery charges from fully depleted to
90% in approximately four hours.
Battery is faulty. Verify that other batteries charge properly. If so, replace the
faulty battery.
Device is not
inserted
correctly in the
cradle.
Remove the device and reinsert it correctly. Verify charging
is active. Touch > System > About phone > Status to
view battery status.
Ambient
temperature of
the cradle is too
warm.
Move the cradle to an area where the ambient temperature
is between 5°C (41°F) and 40°C (104°F).
Spare Battery
Charging LED does
not light when spare
battery is inserted.
Spare battery is
not correctly
seated.
Remove and re-insert the spare battery into the charging
slot, ensuring it is correctly seated.