110 Parameters
01.52 Current day kWh Current day energy consumption. This is the energy of the
last 24 hours (not necessarily continuous) the drive has
been running, not the energy of a calendar day. The value
is set to the value before the power cycle when the drive is
again up and running.
-
0.00…1000000.00
kWh
Energy. 1 = 1 kWh
01.53 Previous day kWh Previous day energy consumption. The value is set to the
value before the power cycle when the drive is again up
and running.
-
0.00 … 1000000.00
kWh
Energy. 1 = 1 kWh
01.54 Cumulative inverter
energy
Amount of energy that has passed through the drive (in
either direction) in full kilowatt-hours. The minimum value
is zero.
-
-200000000.0…
200000000.0 kWh
Energy in kWh. 10 = 1 kWh
01.55 Inverter GWh counter
(resettable)
Amount of energy that has passed through the drive (in
either direction) in full gigawatt-hours. The minimum value
is zero.
You can reset the value by setting it to zero. Resetting any
of parameters 01.55…01.58 resets all of them.
-
0…65535 GWh Energy in GWh. 1 = 1 GWh
01.56 Inverter MWh counter
(resettable)
Amount of energy that has passed through the drive (in
either direction) in full megawatt-hours. Whenever the
counter rolls over, 01.55 Inverter GWh counter
(resettable) is incremented. The minimum value is zero.
You can reset the value by setting it to zero. Resetting any
of parameters 01.55…01.58 resets all of them.
-
0…1000 MWh Energy in MWh. 1 = 1 MWh
01.57 Inverter kWh counter
(resettable)
Amount of energy that has passed through the drive (in
either direction) in full kilowatt-hours. Whenever the
counter rolls over, 01.56 Inverter MWh counter
(resettable) is incremented. The minimum value is zero.
You can reset the value by setting it to zero. Resetting any
of parameters 01.55…01.58 resets all of them.
-
0…1000 kWh Energy in kWh. 10 = 1 kWh
01.58 Cumulative inverter
energy (resettable)
Amount of energy that has passed through the drive (in
either direction) in full kilowatt-hours. The minimum value
is zero.
You can reset the value by setting it to zero. Resetting any
of parameters 01.55…01.58 resets all of them.
-
-200000000.0…
200000000.0 kWh
Energy in kWh. 10 = 1 kWh
01.61 Abs motor speed used Absolute value of the motor speed used 01.01 Motor
speed used.
-
0.00… 30000.00 rpm 1 = 1 rpm
01.62 Abs motor speed % Absolute value of the motor speed % 01.03
Motor speed
%
-
0.00… 1000.00% 10 = 1%
No. Name/Value Description Default
FbEq 16