Parameters 249
40.91 Feedback data
storage
Storage parameter for receiving a process feedback value
eg. through the embedded fieldbus interface.
The value can be sent to the drive as Modbus I/O data.
Set the target selection parameter of that particular data
(58.101…58.114) to Feedback data storage. In 40.08 Set
1 feedback 1 source (or 40.09 Set 1 feedback 2 source),
select Feedback storage.
0.00
-327.68 … 327.67 Storage parameter for process feedback. 100 = 1
40.92 Setpoint data storage Storage parameter for receiving a process setpoint value
eg. through the embedded fieldbus interface.
The value can be sent to the drive as Modbus I/O data.
Set the target selection parameter of that particular data
(58.101…58.114) to Setpoint data storage. In 40.16 Set 1
setpoint 1 source (or 40.17 Set 1 setpoint 2 source),
select Setpoint data storage.
0.00
-327.68 … 327.67 Storage parameter for process setpoint. 100 = 1
40.96 Process PID output % Percentage scaled signal of parameter 40.01 Process PID
feedback actual.
0.00%
-100.00…100.00% Percentage. 100 = 1%
40.97 Process PID feedback
%
Percentage scaled signal of parameter 40.02 Process PID
feedback actual.
0.00%
-100.00…100.00% Percentage. 100 = 1%
40.98 Process PID setpoint
%
Percentage scaled signal of parameter 40.03 Process PID
setpoint actual.
0.00%
-100.00…100.00% Percentage. 100 = 1%
40.99 Process PID deviation
%
Percentage scaled signal of parameter 40.04 Process PID
deviation actual.
0.00%
-100.00…100.00% Percentage. 100 = 1%
41
41 Process PID set 2
A second set of parameter values for process PID control.
The selection between this set and first set (parameter
group 40 Process PID set 1) is made by parameter 40.57
PID set1/set2 selection.
See also parameters 40.01…40.06, and the control chain
diagrams on pages 386 and 387.
41.08 Set 2 feedback 1
source
See parameter 40.08 Set 1 feedback 1 source. Not selected
41.09 Set 2 feedback 2
source
See parameter 40.09 Set 1 feedback 2 source. Not selected
41.10 Set 2 feedback
function
See parameter 40.10 Set 1 feedback function. In1
41.11 Set 2 feedback filter
time
See parameter 40.11 Set 1 feedback filter time. 0.000 s
41.14 Set 2 setpoint scaling See parameter 40.14 Set 1 setpoint scaling.0.00
41.15 Set 2 output scaling See parameter 40.15 Set 1 output scaling. 1500.00;
1800.00
(95.20 b0)
41.16 Set 2 setpoint 1
source
See parameter 40.16 Set 1 setpoint 1 source. Not selected