Program features 95
Diagnostics
Fault and warning messages, data logging
See chapter Fault tracing (page 331).
Signal supervision
Six signals can be selected to be supervised by this function. Whenever a supervised
signal exceeds or falls below predefined limits, a bit in 32.01 Supervision status is
activated, and a warning or fault generated.
The supervised signal is low-pass filtered.
Settings and diagnostics
Parameter group 32 Supervision (page 214).
Events: -
Energy saving calculators
This feature consists of the following functionalities:
• An energy optimizer that adjusts the motor flux in such a way that the total system
efficiency is maximized
• A counter that monitors used and saved energy by the motor and displays them in
kWh, currency or volume of CO
2
emissions, and
• A load analyzer showing the load profile of the drive (see section Load analyzer
on page 95).
In addition, there are counters that show energy consumption in kWh of the current
and previous hour as well as the current and previous day.
Note: The accuracy of the energy savings calculation is directly dependent on the
accuracy of the reference motor power given in parameter 45.19 Comparison power.
Settings and diagnostics
Parameter group 45 Energy efficiency (page 253).
Parameters 01.50 Current hour kWh (page 109), 01.51 Previous hour kWh (page
109), 01.52 Current day kWh (page 110) and 01.53 Previous day kWh (page 110).
Events: -
Load analyzer
Peak value logger
The user can select a signal to be monitored by a peak value logger. The logger
records the peak value of the signal along with the time the peak occurred, as well as