EasyManuals Logo

ABB ACS880 PCP User Manual

ABB ACS880 PCP
494 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #394 background imageLoading...
Page #394 background image
394 Additional parameter data
58.18 EFB control word PB 0000h…FFFFh - 1 = 1
58.19 EFB status word PB 0000h…FFFFh - 1 = 1
58.25 Control profile List 0, 2 - 1 = 1
58.26 EFB ref1 type List 0…5 - 1 = 1
58.27 EFB ref2 type List 0…5 - 1 = 1
58.28 EFB act1 type List 0…6 - 1 = 1
58.29 EFB act2 type List 0…6 - 1 = 1
58.30 EFB status word transparent
source
Analog
src
--1 = 1
58.31 EFB act1 transparent source Analog
src
--1 = 1
58.32 EFB act2 transparent source Analog
src
--1 = 1
58.33 Addressing mode List 0…2 - 1 = 1
58.34 Word order List 0…1 - 1 = 1
58.101 Data I/O 1 Analog
src
--1 = 1
58.102 Data I/O 2 Analog
src
--1 = 1
58.103 Data I/O 3 Analog
src
--1 = 1
58.104 Data I/O 4 Analog
src
--1 = 1
58.105 Data I/O 5 Analog
src
--1 = 1
58.106 Data I/O 6 Analog
src
--1 = 1
58.107 Data I/O 7 Analog
src
--1 = 1
…… … … …
58.124 Data I/O 24 Analog
src
--1 = 1
74 Pump setup
74.01 Pump enable Binary
src
--1 = 1
74.02 Run-time hours reset source Binary
src
--1 = 1
74.03 Gear reduction ratio Real 1.00...1000.00 - 1000 = 1
74.04 Speed ref type List --1 = 1
74.05 Speed ref source Analog
src
-Prpm, rpm
or Hz
1 = 1
74.06 Speed ref Real 0.00...30000.00 Prpm, rpm
or Hz
100 = 1 Prpm,
rpm or Hz
74.07 Minimum rod speed Real -10000.00...10000.00 Prpm, rpm
or Hz
100 = 1 Prpm,
rpm or Hz
No. Name Type Range Unit FbEq32

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS880 PCP and is the answer not in the manual?

ABB ACS880 PCP Specifications

General IconGeneral
Output currentUp to 5200 A
Input voltage380-690 V
Power range5600 kW
Cooling methodAir or liquid
Protection classIP21, IP54
Communication interfacesEthernet, CANopen

Related product manuals