Parameters 125
07.21 Application
environment status 1
Shows which tasks of the application program are running.
See the Drive (IEC 61131-3) application programming
manual (3AUA0000127808 [English]).
-
0000h…FFFFh Application program task status. 1 = 1
07.22 Application
environment status 2
Shows the status of the openings in the application
program.
See the Drive (IEC 61131-3) application programming
manual (3AUA0000127808 [English]).
-
0000h…FFFFh Application program opening status. 1 = 1
07.23 Application name First five ASCII letters of the name given to the application
program in the programming tool. The full name is visible
under System info on the control panel or the Drive
composer PC tool.
_N/A_ = None.
-
07.24 Application version Application program version number given to the
application program in the programming tool. Also visible
under System info on the control panel or the Drive
composer PC tool.
-
07.25 Customization
package name
First five ASCII letters of the name given to the
customization package. The full name is visible under
System info on the control panel or the Drive composer PC
tool.
_N/A_ = None.
-
07.26 Customization
package version
Customization package version number. Also visible under
System info on the control panel or the Drive composer PC
tool.
-
09
09 Pump actuals
Basic signals for monitoring the application.
All parameters in this group are read-only unless otherwise
noted.
09.01 Rod torque Estimated pump torque in engineering units. 0.00 N•m or
lbft
-100000.00
...100000.00
Value range 10 = 1 N•m or
lbft
No. Name/Value Description Def/
FbEq16
Bit Name Description
0 Pre task 1 = Pre-task running.
1 Appl task1 1 = Task 1 running.
2 Appl task2 1 = Task 2 running.
3 Appl task3 1 = Task 3 running.
4…14 Reserved
15 Task monitoring 1 = Task monitoring enabled
Bit Name Description
0 Opening1 Status of opening 1 in the application program.
1 Opening2 Status of opening 2 in the application program.
…… …
15 Opening16 Status of opening 16 in the application program.