Default control connections 97
Sensor connection examples
P
I
6
7
AI2+
AI2-
Actual value measurement
-20…20 mA. R
in
= 100 ohm
XAI
0/4…20 mA
Note: The sensor must be powered externally.
P
I
XAI
+
1+VREF
Reference voltage output
+
P
I
6
7
AI2+
AI2-
Drive 1 / XAI
0/4…20 mA
+
Actual value measurement
-20…20 mA. R
in
= 100 ohm
+24V
6
7
AI2+
AI2-
Drive 2 / XAI
Actual value measurement. -20…20 mA.
R
in
= 100 ohm
6
7
AI2+
AI2-
Drive 3 / XAI
Actual value measurement. -20…20 mA.
R
in
= 100 ohm
6
7
AI2+
AI2-
Actual value measurement
-20…20 mA. R
in
= 100 ohm
3AGND
Ground
0/4…20 mA
OUT
P
I
XAI
+
1+VREF
Reference voltage output
6
7
AI2+
AI2-
Actual value measurement
-20…20 mA. R
in
= 100 ohm
3AGND
Ground
0/4…20 mA
Power
supply

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS880 PCP and is the answer not in the manual?

ABB ACS880 PCP Specifications

General IconGeneral
Output currentUp to 5200 A
Input voltage380-690 V
Power range5600 kW
Cooling methodAir or liquid
Protection classIP21, IP54
Communication interfacesEthernet, CANopen