126 Parameters
09.02 Maximum rod torque Maximum allowed pump torque in engineering units. 0.00
-100000.00
...100000.00
Value range 10 = 1 N•m or
lbft
09.03 Motor torque Actual motor torque in engineering units. 0.00 N•m or
lbft
-100000.00
...100000.00
Value range 10 = 1 N•m or
lbft
09.04 Maximum motor
torque
Maximum allowed motor torque in engineering units. 0.00 N•m or
lbft
-100000.00
...100000.00
Value range 10 = 1 N•m
or lbft
09.05 Rod speed Pump speed in engineering units. 0.00 Prpm,
rpm or Hz
-100000.00
...100000.00
Value range 10 = 1 Prpm,
rpm or Hz
09.06 Motor speed
reference
Motor speed reference in engineering units. 0.00 rpm or
Hz
-100000.00
...100000.00
Value range 10 = 1 rpm or
Hz
09.07 Run-time hours Runtime of the pump in hours. 0.00 h
0.00....100000.00 Value range 10 = 1 h
09.08 Fluid level Measured fluid level in depth units. 0.00 m, ft or
Joints
-100000.00
...100000.00
Value range 10 = 1 m, ft or
Joints
09.09 Pressure Measured pressure in engineering units. 0.00 kPa or
psi
-100000.00
...100000.00
Value range 10 = 1 kPa or
psi
09.10 Measured
temperature
Measured temperature in engineering units. 0.00 °C
-100000.00
...100000.00
Value range 10 = 1 °C
09.11 Backspin speed
reference
Speed reference for controllable shutdown procedure. 0.00 Prpm,
rpm or Hz
-100000.00
...100000.00
Value range 10 = 1 Prpm,
rpm or Hz
09.12 Start delay remain Remaining start delay time. 0.000s
0…4294967.295 Value range 10 = 1 s
09.13 Backspin status word Pump backspin status word. 0000h
No. Name/Value Description Def/
FbEq16