396 Additional parameter data
75.14 Sleep signal source 1 Analog
src
--1 = 1
75.15 Sleep signal source 2 Analog
src
--1 = 1
75.16 Sleep level Real 0.00...100000000.00 % 100 = 1%
75.17 Sleep delay time Real 0.000...10000.000 s 1000 = 1 s
75.18 Wakeup level Real 0.00...100000000.00 % 100 = 1%
75.19 Wakeup delay time Real 0.000...10000.000 s 1000 = 1 s
75.20 Maximum sleep time Real 0.000...100000.000 s 1000 = 1 s
76 Pump pressure protection
76.01 Pressure protection function List --1 = 1
76.02 Pressure protection latching List 0...2 - 1 = 1
76.03 Digital feedback source enable Binary
src
--1 = 1
76.04 Digital feedback source Binary
src
--1 = 1
76.05 Analog feedback source
enable
Binary
src
--1 = 1
76.06 Analog feedback source Analog
src
--1 = 1
76.07 Analog feedback limit Real 0.00...10000.00 kPa or psi 100 = 1 kPa
or psi
76.08 Analog feedback limit delay
time
Real 0.000...3600.000 s 1000 = 1 s
77 Pump torque protection
77.01 Rod torq limit display List --1 = 1
77.02 Rod torq1 function Binary
src
--1 = 1
77.03 Rod torq1 limit type List --1 = 1
77.04 Rod torq1 limit Real 0.00...10000.00 N•m, lbft
or A
100 = 1 N•m,
lbft or A
77.05 Rod torq1 speed Real -3600.00...3600.00 Prpm, rpm
or Hz
100 = 1 Prpm,
rpm or Hz
77.06 Rod torq1 delay time Real 0.000...10000.000 s 1000 = 1 s
77.07 Rod torq2 function Binary
src
--1 = 1
77.08 Rod torq2 limit type List --1 = 1
77.09 Rod torq2 limit Real 0.00...10000.00 N•m, lbft
or A
100 = 1 N•m,
lbft or A
77.10 Rod torq2 delay time Real 0.000...10000.000 s 100 = 1 s
77.11 Rod torq2 additive speed ref Real -3600.00...3600.00 Prpm, rpm
or Hz
100 = 1 Prpm,
rpm or Hz
77.12 Rod torq2 speed delay time Real 0.000...100000.000 s 1000 = 1 s
77.13 Rod torq2 limit counter Real 0...100 - 1 = 1
77.14 Rod torq2 time window Real 0.000...7200.000 s 1000 = 1 s
No. Name Type Range Unit FbEq32