Changing the Default Settings 4
U1253B User’s and Service Guide 85
Default Factory Settings and Available Setting Options
The following table shows the various menu items with their
respective default settings and available options.
Table 4- 1 Default factory settings and available setting options for each feature
Menu Feature
Default factory
setting Available setting options
1
RHOLD 500 Refresh hold.
• To enable this function, select a value within the range of 100 to 9900.
• To disable this function, set all digits to zero (“OFF” will be indicated).
Note: Select OFF to enable data hold (manual trigger).
D-LOG HAND Available options for data logging:
• HAND: manual data logging.
• TIME: interval (automatic) data logging, where the interval is according
to the LOG TIME setting.
LOG TIME 0001 S Logging interval for interval (time) data logging. Select a value within the
range of 0001 second to 9999 seconds.
dB dBm • Available options: dBm, dBV, or OFF.
• Select OFF to disable this function for normal operation.
dBm-R 50 Ω Reference impedance value for dBm measurement. Select a value within
the range of 1 Ω to 9999 Ω.