12 U1253B User’s and Service Guide
1Getting Started
Table 1-2 Keypad descriptions and functions
Button Function when pressed for less than 1 second Function when pressed for more than 1 second
1 cycles through OLED display brightness
levels.
enters Log Review mode. Press to switch
between manual or interval logging data.
Press or to view first or last logged data
respectively. Press or to scroll through the
logged data.
Press for more than 1 second to exit this mode.
2 holds the current measured value.
In Data Hold mode ( ), press
again to trigger the holding of the next
measured value. Press for more than 1
second to exit this mode.
In Refresh Hold mode ( ), the reading
is updated automatically once the reading is
stable and the count setting is exceeded
[1]
.
Press again to exit this mode.
enters the Dynamic Recording mode.
Press again to scroll through maximum,
minimum, average, or present readings (indicated by
, , , or
on the display).
Press for more than 1 second to exit this mode.
3 saves the displayed value as a
reference to be subtracted from subsequent
measurements.
While in null mode, press to view the
relative value ( ) that has been saved.
The saved relative value will be displayed for
3 seconds.
Press while the relative value ( )
is being displayed to cancel the Null function.
enters the 1 ms Peak Hold mode.
Press to scroll through maximum ( )
and minimum ( ) peak readings.
Press for more than 1 second to exit this mode.
4 scrolls through the measurement
function(s) of the present rotary switch
selection.
enters the Setup mode.
In the Setup mode, press or to navigate through
the menu pages. Press or to scroll through the
available settings.
Press to edit the specified value.
Press again to save the new settings and exit the
editing mode, or press to exit without saving.
Press for more than 1 second to exit this mode.
5 scrolls through the available
measurement ranges (except when the rotary
switch is at the or position)
[2]
.
enters the Auto Range mode.

Table of Contents

Other manuals for Agilent Technologies U1253B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies U1253B and is the answer not in the manual?

Agilent Technologies U1253B Specifications

General IconGeneral
BrandAgilent Technologies
ModelU1253B
CategoryMultimeter
LanguageEnglish

Related product manuals