Comissioning a Generic Encoder with BISS-C Interface
Function description32
Version: 1.5
7.7.5 Parameter Channel / Data / BISS
Most encoders will run with the preset default values.
Do not change any settings unless you are sure that your specific encoder requires that!
Some explanations (referring to the numbers in the picture):
1. The settings are the same for most common encoders and will be preset.
2. Mcd (multi cycle data) is not used here. Keep values 0.
3. Use "Min. clock speed" and "Max. clock speed "from encoder datasheet if available. If you need to
change this, see below chapter “Restrictions for Clock Frequency”.
4. Register mode is not used. Keep settings as preset.
5. Keep values 0 (except in some cases for “Pretrigger time encoder to sync” as described below).