1 689 979 672 2012-06-26| Robert Bosch GmbH
Technical Data | EPS 807 / 815 | 45 en
9.2 Permissible ambient temperature
ranges
Property Value/Range
Maximum ambient temperature: 40 °C
Operating range: 5 – 40 °C
Accuracy: 10 – 35 °C
Storage temperature: -25 – 60 °C
9.� Permissible Clutch torque
Property EPS807 EPS815
Clutch torque:
Short time, approx. 2 min.
Continuous operation
min
-1
Nm
Nm
0 to 850
100
65
1500
68
44
2500
37,5
25
0 to 850
250
170
1500
98
72
2500
54
37
9.4 Pressure and Fluid capacities
Property EPS807 EPS815
MGT KMA MGT KMA
Delivery pump capacity:
Calibration fluid low pressure
Calibration fluid high pressure
kPa
l/min
MPa
l/min
0 – 600
0 – 22
0 – 6
0 – 1,4
0 – 600
0 – 22
0 – 6
0 – 1,4
0 – 600
0 – 22
0 – 6
0 – 1,4
0 – 600
0 – 22
0 – 6
0 – 1,4
Pressure gauges:
Low pressure
High pressure
Vacuum/internal pump pressure
Delivery pump pressure
kPa
MPa
kPa
MPa
0 – 600
0 – 6
-100 – 0 – 250
0 – 1,6
0 – 600
0 – 6
-100 – 0 – 250
0 – 1,6
0 – 600
0 – 6
-100 – 0 – 250
0 – 1,6
0 – 600
0 – 6
-100 – 0 – 250
0 – 1,6
Lubricating oil pressure (optional accessory) MPa
l/min
0 –10
0 – 5,8
0 –10
0 – 5,8
0 –10
0 – 5,8
0 –10
0 – 5,8
Thermometer:
Calibration fluid heating: electric
Cooling-water consumption at the individually supplied
test bench power and a cooling-water temperature of 17 °C
Temperature measuring range
Temperature measuring range
°C
KW
l/min
°C
°C
approx. 2,2
9
30 – 60
-40 – 150
approx. 2,2
9
30 – 60
-40 – 150
approx. 2,2
9
30 – 60
-40 – 150
approx. 2,2
9
30 – 60
-40 – 150
Fluid capacities:
Calibration fluid
Storage area for contaminated oil
Lubricating oil (optional accessory)
l
l
l
50
6
12
50
6
12
50
6
12
50
6
12
9.5 Test-bench colour
Green RAL 6018
Anthracite RAL 7016