PurposeCommand or Action
Configures the interface as a port access entity
(PAE) authenticator.
dot1x pae authenticator
Example:
Switch(config-if)# dot1x pae authenticator
Step 6
Enables Port Fast on an access port connected to
a single workstation or server..
spanning-tree portfast
Example:
Switch(config-if)# spanning-tree portfast trunk
Step 7
Returns to privileged EXEC mode.end
Example:
Switch(config-if)# end
Step 8
Verifies your configuration.
show running-config interface interface-id
Example:
Switch# show running-config interface
Step 9
gigabitethernet2/0/1
(Optional) Saves your entries in the configuration
file.
copy running-config startup-config
Example:
Switch# copy running-config startup-config
Step 10
Configuring a Supplicant Switch with NEAT
Beginning in privileged EXEC mode, follow these steps to configure a switch as a supplicant:
Catalyst 2960-X Switch Security Configuration Guide, Cisco IOS Release 15.0(2)EX
342 OL-29048-01
Configuring IEEE 802.1x Port-Based Authentication
Configuring a Supplicant Switch with NEAT