Table 7: Air Flow Specifications and Fan Tray Support
Air VolumeAir Filter AvailableAirflow ExhaustAirflow IntakeFan Tray Model Number
850 CFMNoLeft sideRight sideC6807-XL-FAN
Figure 6: Air Flow Direction
Module air exhaust3Module air inlet1
Power supply air exhaust4Power supply air inlet2
Humidity
High-humidity conditions may cause moisture to enter the system, and cause corrosion of internal components
and degradation of properties such as electrical resistance, thermal conductivity, physical strength, and size.
Extreme moisture buildup inside the system may result in electrical short circuit, which may cause serious
damage to the system. Each system is rated to operate at 5 to 90 percent relative humidity, with a humidity
gradation of 10 percent per hour. In storage, a system can withstand 5 to 95 percent relative humidity. Buildings
in which climate is controlled by air-conditioning in the warmer months and by heat during the colder months
usually maintain an acceptable level of humidity for system equipment. However, if a system is located in an
unusually humid location, a dehumidifier should be used to maintain the humidity within an acceptable range.
Cisco Catalyst 6807-XL Switch Hardware Installation Guide
OL-30656-01 17
Preparing for Installation
Humidity

Table of Contents

Other manuals for Cisco Catalyst 6807-XL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 6807-XL and is the answer not in the manual?

Cisco Catalyst 6807-XL Specifications

General IconGeneral
BrandCisco
ModelCatalyst 6807-XL
CategorySwitch
LanguageEnglish

Related product manuals