Related FW 2.5.0 Related applications
Comm object 1107
Description
Output closes if the shutdown alarm for AIN6 activates.
The output opens, if
Alarm is not active and
FAULT RESET is pressed
Sd AIN6
6 back to List of LBO
Related FW 2.5.0 Related applications
Comm object 1158
Description
Output closes if the shutdown alarm for AIN7 activates.
The output opens, if
Alarm is not active and
FAULT RESET is pressed
Sd AIN7
6 back to List of LBO
Related FW 2.5.0 Related applications
Comm object 1159
Description
Output closes if the shutdown alarm for AIN8 activates.
The output opens, if
Alarm is not active and
FAULT RESET is pressed
Sd AIN8
6 back to List of LBO
Related FW 2.5.0 Related applications
Comm object 1160
Description
Output closes if the shutdown alarm for AIN9 activates.
The output opens, if
Alarm is not active and
FAULT RESET is pressed
Sd AIN9
6 back to List of LBO

Table of Contents

Other manuals for ComAp InteliDrive Lite

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive Lite and is the answer not in the manual?

ComAp InteliDrive Lite Specifications

General IconGeneral
BrandComAp
ModelInteliDrive Lite
CategoryController
LanguageEnglish

Related product manuals