EasyManuals Logo
Home>Dahua>Network Hardware>NVR100 series

Dahua NVR100 series User Manual

Dahua NVR100 series
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
134
Figure 2-82
Icon
Function
116
ALARM1ALARM16. The alarm becomes activated in the
low level.
NO1 C1NO2 C2NO3 C3NO4
C4
Four NO activation output groups. (On-off button).
NO5 C5 NC5
One NO/NC activation output group. (On-off button).
CTRL 12V
Control power output. Disable power output when alarm is
canceled. Current is 500mA.
12V
Rated current output. Current is 500mA.
GND
A/B
485 communication port. They are used to control devices
such as PTZ. Please parallel connect 120TΩ between A/B
cables if there are too many PTZ decoders.
Note
Different models support different alarm input ports. Please refer to the specifications sheet for
detailed information.
Slight difference may be found on the alarm port layout.
2.3.2 Alarm input port
Connect the positive end (+) of the alarm input device to the alarm input port (ALARM IN 116) of the
NVR. Connect the negative end (-) of the alarm input device to the ground end ( ) of the NVR.