12.6 VEHICLE SPEED DEPENDENT FLOW COMMAND LIMITATION
GPS algorithm type = GPS v1
Using the auto-guidance function, the PVED-CLS’s auto-guidance control algorithm can also limit the maximum allowed
output flow in proportion to the vehicle speed (i.e. the faster the vehicle goes the lower the maximum allowed flow will
be).
Speed range [km/h]: 0 to 100 for P3453 and P3457
Range [IR]: 0 to 1000 for P3451, P3455 and P3459
Important
This function applies to both GPS and GPS2.
These parameters represent the three points on the curve below (Point D, E and F). The auto-guidance algorithm will make
linear interpolation in between each of the three points. It is allowed to move the three points in any direction, limited by
the following rules:
Point D is always specified at Vehicle speed limited flow = 0 km/h
Point F “Max flow” is valid for Point F and vehicle speeds above Point F
Point D “Max flow” ≥ Point E “Max flow” ≥ Point F “Max flow”
Point F “Vehicle speed limited flow” > Point E “Vehicle speed limited flow” > Point D “Vehicle speed limited
flow”
Figure 68
Warning
Failure to comply with the above rules may render this function inoperable or lead to undesirable steering
behavior!

Table of Contents

Other manuals for Danfoss PVED-CLS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVED-CLS and is the answer not in the manual?

Danfoss PVED-CLS Specifications

General IconGeneral
BrandDanfoss
ModelPVED-CLS
CategoryController
LanguageEnglish

Related product manuals