© Danfoss | August 2018 AQ00000211 | 111
ENGINEERING TOMORROW
Warning
Failure to comply with the above rules may render this function inoperable or lead to undesirable steering
behavior!
Name
Address
Data type
Unit
Description of parameter
User
Range
Danfoss default
value
Safety critical
parameters ‘S’
Min.
Max.
AUX joystick - Flow
limit for max joystick
command @ Point M
P3690 U16 IR
Aux Joystick: flow limit for maximum joystick command at Vehicle speed
of 0 km/h
OEM 0 1000 1000
AUX joystick - Flow
limit for max joystick
command @ Point N
P3692 U16 IR
Aux Joystick - flow limit for maximum joystick command at the vehicle
speed of "Aux Joystick - Vehicle speed @ Point N"
OEM 0 1000 50
AUX joystick - Flow
limit for max joystick
command @ Point O
P3694 U16 IR
Aux Joystick - flow limit for maximum joystick command at the vehicle
speed of "Aux Joystick - Vehicle speed @ Point O"
OEM 0 1000 25
AUX joystick - Vehicle
speed @ Point N
P3696 U8 km/h
Aux Joystick - Vehicle speed to limit the flow @ point N for maximum
joystick command
OEM 0 100 15
AUX joystick - Vehicle
speed @ Point O
P3697 U8 km/h
Aux Joystick - Vehicle speed to limit the flow @ point O for maximum
joystick command
OEM 0 100 25
Table 48
11.10 CLOSED LOOP JOYSTICKVEHICLE SPEED DEPENDENT WHEEL ANGLE LIMITATION
As a risk mitigation method, when using a Closed Loop Joystick function, the PVED-CLS’s Closed Loop Joystick control
algorithm can limit the maximum allowed angle, that the wheels can be moved to, in proportion to the vehicle speed (i.e.
the faster the vehicle goes, the narrower the maximum allowed angle, that the wheel can be moved to, will be).
The range is from 0 to 100 km/h for P3723 and P3724 and from 0 to 89 [°] for P3720, P3721 and P3722.
These parameters represent the three points on the curve below (Point A, B and C). The Closed Loop Joystick-algorithm
will make linear interpolation in between each of the three points. It is allowed to move the three points in any direction,
limited by the following rules:
Point A is always specified at Vehicle speed limiting wheel angle = 0 km/h
Point C “Max wheel angle” is valid for Point C “Vehicle speed limiting wheel angle” and vehicle speeds above
Point C “Vehicle speed limiting wheel angle”
Point A “Max wheel angle” ≥ Point B “Max wheel angle” ≥ Point C “Max wheel angle”
Point C “Vehicle speed limiting wheel angle” > Point B Vehicle speed limiting wheel angle” > Point A “Vehicle
speed limiting wheel angle”

Table of Contents

Other manuals for Danfoss PVED-CLS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVED-CLS and is the answer not in the manual?

Danfoss PVED-CLS Specifications

General IconGeneral
BrandDanfoss
ModelPVED-CLS
CategoryController
LanguageEnglish

Related product manuals