17.3 FMI LIST
In PVED-CLS the standard FMI from J1939-73 Appendix A page 130 are used as much as possible. However, in some
cases some of the reserved area FMI’s are redefined to suit the need.
The List of FMI’s used in PVED-CLS is found below:
Index Failure mode
0 - Data valid, but above normal operational range - Most severe level
1 - Data valid, but below normal operational range - Most severe level
2 - Data erratic, intermittent or incorrect
3 - Voltage above normal or short-circuit to high source
4 - Voltage below normal or short-circuit to low source
5 - Current below normal or open circuit
6 - Current above normal or grounded circuit
7 - Mechanical system not responding or out of adjustment
8 - Abnormal frequency or pulse width or period
10 - Abnormal rate of change
12 - Bad intelligent device or component
14 - Special instructions
15 - Data valid, but above normal operating range - Least severe level
16 - Data valid, but above normal operating range - Moderately severe level
17 - Data valid, but below normal operating range - Least severe level
18 - Data valid, but below normal operating range - Moderately severe level
19 - Received network data in error
25 - Signal crosscheck failed
27 - Unable to return to neutral
28 - Not in neutral at Power-up
Table 63