© Danfoss | August 2018 AQ00000211 | 15
ENGINEERING TOMORROW
Min.
Max.
Cut-off valve present P3072 U8 -
Cut-off Valve Present/Not Present
Valid Values: 0 (NOT PRESENT); 255 (PRESENT)
OEM 0 255 255 S
Valve type P3081 U8 -
Valve type on which the PVED-CLS is mounted
Valid Values: 0 (OSPE, EHi-E); 1 (EHPS); 2 (EHi-H)
OEM 0 2 0 S
OSP displacement P3084 U16 ccm
OSP displacement, number of cubic centimeters per revolution
Note: When the PVED-CLS is mounted on an EHPS this parameter
must be set equal to 0!
OEM 0
120
0
120 S
Cylinder stroke volume P3086 U16 ccm
Cylinder stroke volume.
Acceptable values: 100-10000.
Note: Writing values >10000 will force to use automatic adjusted
cylinder stroke volume-value on WAS calibration
OEM 100
655
35
500 S
Table 1
For further information on how to design steering-system and sensor sub-systems, please refer to the following:
OSPE Steering valve Technical information
SASA sensor Technical information
PVED-CLS Safety Manual
EHi Technical information
Important
The number of steering wheel turns Lock-to-lock is dependent on following:
OSP displacement
EH-spool and pilot flow
Standby pressure (spring force)
Cylinder volume

Table of Contents

Other manuals for Danfoss PVED-CLS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVED-CLS and is the answer not in the manual?

Danfoss PVED-CLS Specifications

General IconGeneral
BrandDanfoss
ModelPVED-CLS
CategoryController
LanguageEnglish

Related product manuals