© Danfoss | August 2018 AQ00000211 | 17
Name
Description of parameter
Range
critical
Cut-off valve present P3072 U8 -
Cut-off Valve Present/Not Present
Valid Values: 0 (NOT PRESENT); 255 (PRESENT)
OEM 0 255 255 S
Invert flow direction P3080 U8 -
Changes the direction of the requested flow
Valid Values: 0 (NO, DEFAULT OSPE/EHi); 255 (YES, DEFAULT
OEM 0 255 0 S
Valve type P3081 U8 -
Valve type on which the PVED-CLS is mounted
Valid Values: 0 (OSPE, EHi-E); 1 (EHPS); 2 (EHi-H)
OEM 0 2 0 S
P3082 U16 -
Number of steering wheel turns lock-to-lock, without PVED-CLS activated
(hence pure hydraulic Resolution: 0.01 turns)
OEM 100 1000 450 S
OSP displacement P3084 U16 ccm
OSP displacement, number of cubic centimeters per revolution
Note: When the PVED-CLS is mounted on an EHPS this parameter
OEM 0 1200 120 S
Cylinder stroke volume P3086 U16 ccm
Acceptable values: 100-10000.
Note: Writing values >10000 will force to use automatic adjusted
cylinder stroke volume-value on WAS calibration
OEM 100 65535 500 S
Table 2
For further information on how to design steering-system and sensor sub-systems, please refer to the following:
• OSPE Steering valve Technical information
• SASA sensor Technical information
• PVED-CLS Safety Manual
• EHPS Steering Valve, PVE Actuation, OSPCX CN Steering Unit