EasyManuals Logo
Home>Danfoss>Controller>PVED-CLS

Danfoss PVED-CLS User Manual

Danfoss PVED-CLS
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
94 | © Danfoss | August 2018 AQ00000211
ENGINEERING TOMORROW
Name
Address
Data type
Unit
Description of parameter
User
Range
Danfoss default
value
Safety critical
parameters ‘S’
Min.
Max.
STW soft-stop wheel
angle region start
P3562 U16 IR
Defines the wheel angle region start, from the max possible wheel angle
towards 0, in which the soft stop has to be applied
OEM 0 1000 400
STW soft-stop max flow
@ cylinder end-stop
P3564 U16 IR Oil flow to deliver at the max possible wheel angle OEM 0 1000 0
STW soft-stop wheel
angle region end
P3566 U16 IR
Defines the wheel angle region end, from the max possible wheel angle
towards 0, in which the soft stop region shall end
OEM 0 1000 0
Table 40

Table of Contents

Other manuals for Danfoss PVED-CLS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVED-CLS and is the answer not in the manual?

Danfoss PVED-CLS Specifications