FC 300 Design Guide
How to Install
" Grounding of Shielded/Armored Control Cables
Generally speaking, control cables must be braided shielded/armored and the shield must be connected
by means of a cable clamp at both ends to the metal cabinet of the unit.
The drawing below indicates how correct grounding is carried out and what to do if in doubt.
a. Correct grounding
Control cables and cables for serial
communication must be fitted with cable
clamps at both ends to ensure the best
possible electrical contact.
b. Wrong grounding
Do not use twisted cable end s (pigtails).
They increase the shield impe dance at
high frequencies.
c. Protection with respect to ground potential
between PLC and VLT
If the ground potential between the adjustable
frequency drive and the PLC (etc.) is different,
electric noise may occur that will disturb
the entire system. Solve this problem
by fitting an equalizing cable, next to the
control cable. Minimum cab le cross-se ction:
0.025 in.
2
(16 mm
2
).
d. For 50/60 Hz ground l oops
If very long control cables are used, 50/60 Hz
ground loops may occur. Solve this problem by
connecting one end of the shield to ground via
a 100nF capacitor (keeping leads short).
e. Cables for serial communication
Eliminate low-frequency noise currents
between two adjustable fre quency drives by
connecting one end of the shield to terminal
61. This terminal is connected to ground via
an internal RC link. Use twisted-pair cables
to reduce the differential mode interfere nce
between the conductors.
109
MG.33.B3.22 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals